Error codes

Most Common Controllers Error Codes
and their Meaning

iGS-061

Adu 1

CO2 sensor overflow (> 5,000 ppm): calibrate sensor[1]

Adu 2

CO2 sensor calibration needed

Adu 3

Recovered data: verify settings

Err 3

CO2 sensor failure[2]

Err 4

Temperature sensor failure2

Err 6

Automatic system recovery has failed2

Alr 3

Temperature < Low Temp Shut Off

Alr 4

Temperature > High Temp Shut Off


[1].    If the CO2 reading is wrong, you can recalibrate the CO2 sensor. See the procedure

[2].     Disconnect and restart your controller. If the problem lasts, reset the controller (see procedure). If the problem lasts, call PLUG'n'GROW at 1-888-577-6274 or chat with an agent at info@igrowing.ca

iGS-100

Err 1

CO2 sensor overflow (> 5,000 ppm): calibrate1

Err 2

CO2 sensor calibration needed

Err 3

CO2 sensor failure

iGS-110

Err 4

Temperature / Relative Humidity sensor failure2

iGS-200

Err 1

CO2 sensor overflow (> 5,000 ppm): calibrate1

Err 2

CO2 sensor calibration needed

Err 3

CO2 sensor failure2

Err 4

Humidity sensor failure2

Err 5

Humidity alarm

Err 6

< 2 hours power failure: make sure the clock in on time

Err 7

2 to 36 hours power failure: make sure the clock in on time

Err 8

> 36 hours power failure: enter current time

iGS-210

Err 1

CO2 sensor overflow (> 5,000 ppm): calibrate1

Err 2

CO2 sensor calibration needed

Err 3

CO2 sensor failure2

Err 4

Temperature sensor failure2

Err 5

Temperature alarm

Err 6

< 2 hours power failure: make sure the clock in on time

Err 7

2 to 36 hours power failure: make sure the clock in on time

Err 8

> 36 hours power failure: enter current time

iGS-220

Adu 1

CO2 sensor overflow (> 5,000 ppm): calibrate sensor1

Adu 2

CO2 sensor calibration needed

Adu 3

Recovered data: verify settings

Adu 6

< 2 hours power failure: make sure the clock is on time

Adu 7

2 to 36 hours power failure: make sure the clock is on time

Adu 8

> 36 hours power failure: enter current time

Err 3

CO2 sensor failure2

Err 4

Temp./Relative Humidity sensor failure2

Err 6

Automatic system recovery has failed2

Alr 1

Relative Humidity < Low limit

Alr 2

Relative Humidity > High limit

Alr 3

Temperature < Low limit

Alr 4

Temperature > High limit

Alr 5

Emergency mode is activated[1]

Alr 6

Cooling limit reached while dehumidifying3


[1].     Verify the alarms settings and limit values. Look at the user guide to better understand these functions.

If the problem lasts, call PLUG'n'GROW, toll free at 1-888-577-6274

 