Aller directement au contenu
Dealer Access Changer la langue à : Français »
For better harvests.
  • Normal text
  • Medium text
  • Large text
  • RSS Feed
  • Print
  • Send to a friend

Timers

PLUG'N'GROW timers are precise tools made and designed for hydroponic gardening. They are used to repeat operations upon a selected cycle by the user and corresponding to his needs. In hydroponic gardening, timers are used to activate a watering pump or to open or close a watering valve. They can also be used to activate a fog dispenser or to control intake or extraction fans to change air periodically. Each timer control module can manage added 120 Volts electric loads up to a maximum of 15 Amperes.

The PLUG'N'GROW timers can also activate at the same time multiple loads of 110-120 or 220-240 Volts and using a total of more than 15 Amperes. To control loads up to 40 Amperes of 110-120 or 220-240 Volts, one can plug the trigger cord of a PLUG'N'GROW ILS4 switch box (4 loads or more with a multi-outlets strip) into the timer and feed the iLS4 from a separate electric circuit.


iGS-010

discontinued

iGS-011 iGS-015iGS-016
Controlled equipments Pump, valve, CO2 enrichment, fan Pump, valve, CO2 enrichment, fan

Lighting

or pump

Lighting and pump

combined timers

Single purpose timer

Single purpose timer Single purpose timer  Multi purpose
Light/Darkness Detection Yes Yes Yes Yes
Time display Analogic bar scale No Green digits and messages
Green digits and messages
Displayed mode: Light or Darkness Yes
Separate programs for light and darkness Yes Continuous Cycle or day only Yes Lit condition or continuous cycle

Remaining time before

next ON or

next OFF

Yes Yes Position in lighting cycle displayed
Adjustable functioning time Select among 39 options from 5 seconds to 60 minutes Adjust from 30 seconds to 30 minutes Extra flexible between 1 second and 72h59m59s

Lighting: between

1 hour and

72h59m59s

 

Pump:between 1 second and 72h59m59s

Selectable delays between ON cycles Select among 39 options from 1 minute to 12 hours Adjust from 1 minute to 12 hours  From 1 second to time remaining in cycle
  From 1 second to time remaining in cycle
One equipement 110-120 Volts Yes Yes  Yes
Other climate variables monitored

- Temperature

- Lights ON

- Tank level

- Pump flow

Multiple equipments

4 Outlets:

Lights

Lights cooling

Pump 1 - Main

Pump 2 emergency

Multiple equipements with iLS4 loads switcher** Yes Yes Recommended for lights
Recommended for lights

 

  • IGS-011 Lighted garden or 24 hours timer
  • IGS- 012 Overheating lighting watchdog with restart variable delay
  • ILS4-120 Load switcher 120 V-120 V with restart variable delay from 0 to 20 minutes
  • ILS4-120S Load switcher 240 V - 120 V with restart variable delay from 0 to 20 minutes
  • ILS4-240 Load switcher 240 V- 240 V with restart variable delay from 0 to 20 minutes

Chat with an agent at info@igrowing.ca or call, toll free, at 1-888-577-6274

Developped by Numérique Technologies

Last updated on : February 5, 2012

© 2008 Plug "N" Grow