Aller directement au contenu
Changer la langue à : Français »
For better harvests.
  • Normal text
  • Medium text
  • Large text
  • RSS Feed
  • Print
  • Send to a friend

iGS-LP4X and iGS-LP8X; iGS-NG4X and iGS-NG8X

12,000 or 24,000 BTU with Heat Exchanger Liquid Propane or Natural Gas CO2 Generator

iGS-LP4X/iGS-LP8XFeatures

  • Made of aluminum: 50 % lighter than steel, durable (no rust)
  • Safe, easy to use and highly energy efficient
  • Safety panels surfaces to avoid burning at the touch
  • Safe electronic pilot: no manual starting button nor continuous flame
  • Internal electronic control to avoid excessive heating and to turn off the unit in case of tipping over
  • Warranty one (1) year. Periodic maintenance by the user is required (tool included).
  • Heat exchanger helps keep a cooler temperature inside the greenhouse or grow room without affecting the CO2 and humidity levels
  • Connect to heat exchanger 6 inches diameter flexible or rigid ventilation tubing and use a fan to exhaust heat (2 metal sheets adapters included)
  • Heat exchanger may be ducted to supply heat to living space (fan suggested) without introducing CO2
  • D: 16.5" - H: 20.5" - W: 9.5"
 

Number of CO2 PLUG'n'GROW generators required

to attain 1,500 ppm in 3-5 minutes, depending on your room size and volume:

Room size

Volume

Recommended number of
CO2 generators

Feet

m3

Cu. ft.

iGS-LP4X

iGS-NG4X 

iGS-LP8
iGS-LP8X

iGS-NG8X 

10 x 8 x 8

18

640

1

---

10 x 10 x 8

23

800

1

---

10 x 12 x 8

27

960

1

---

10 x 14 x 8

32

1120

2

1

12 x 16 x 8

43

1530

2

1

12 x 25 x 8

68

2400

---

2

15 x 35 x 8

119

4200

---

3

20 x 40 x 8

181

6400

---

4

25 x 40 x 8

227

8000

---

4

Lab-tested validated data measured in a room at 86°F (30°C); initial CO2 concentration 400 ppm; at sea level; air tight; without plants. Temperature, initial CO2 concentration and altitude affect time needed to attain CO2 levels. Reaching an expected concentration is longer with a high plant density, and in a room with unsealed openings.
 

PLUG'n'GROW heat exchanger outputs vs fan capacity

on iGS-LP4X and iGS-LP8X

Flow cu.ft./min.

(CFM)

Heat exchanger output

(%)

400

30

300

25

200

20

100

15

Output measured at 89.6°F (32°C), relative humidity 32%, sea level and flow provided by squirrel-cage fan. Fan type, air flow, inlet air temperature, air humidity and altitude substantially impact heat exchanger outputs. The colder the inlet air, the better will be your heat exchanger output.

 

Useful Tips

  • schéma 1Plug CO2 generator sense cord to a CO2 controller like iGS-061, iGS-100 or iGS-220 to control CO2 concentration in your grow room or greenhouse.
  • To control many CO2 generators with the same controller, you can plug a power strip in the controller outlet and plug up to 5 CO2 generators in the power strip
  • Cool this generator by drawing air from outside through the sealed heat exchanger without venting out the CO2!

For more information, contacts us at 1-888-577-6274.

 

« Return to CO2 generators

Developped by Numérique Technologies

Last updated on : March 11, 2010