FeaturesWARNING FIRE HAZARD GENERATOR TOP REACHES HIGH TEMPERATURE |
Install and maintain at least an 18 inches (45 cm) distance between the top of the generator and the ceiling or any other combustible material to avoid causing fire |
|
Number of CO2 PLUG'n'GROW generators required to attain 1,500 ppm in 3-5 minutes, depending on your room size and volume: |
||||
|
Room size |
Volume |
Recommended number of |
||
|
Feet |
m3 |
Cu. ft. |
iGS-LP4X iGS-NG4X |
iGS-LP8 iGS-NG8X |
|---|---|---|---|---|
|
10 x 8 x 8 |
18 |
640 |
1 |
--- |
|
10 x 10 x 8 |
23 |
800 |
1 |
--- |
|
10 x 12 x 8 |
27 |
960 |
1 |
--- |
|
10 x 14 x 8 |
32 |
1120 |
2 |
1 |
|
12 x 16 x 8 |
43 |
1530 |
2 |
1 |
|
12 x 25 x 8 |
68 |
2400 |
--- |
2 |
|
15 x 35 x 8 |
119 |
4200 |
--- |
3 |
|
20 x 40 x 8 |
181 |
6400 |
--- |
4 |
|
25 x 40 x 8 |
227 |
8000 |
--- |
4 |
| Lab-tested validated data measured in a room at 86°F (30°C); initial CO2 concentration 400 ppm; at sea level; air tight; without plants. Temperature, initial CO2 concentration and altitude affect time needed to attain CO2 levels. Reaching an expected concentration is longer with a high plant density, and in a room with unsealed openings. | ||||
|
PLUG'n'GROW heat exchanger outputs vs fan capacity on iGS-LP4X and iGS-LP8X |
|
|
Flow cu.ft./min. (CFM) |
Heat exchanger output (%) |
|---|---|
|
400 |
30 |
|
300 |
25 |
|
200 |
20 |
|
100 |
15 |
| Output measured at 89.6°F (32°C), relative humidity 32%, sea level and flow provided by squirrel-cage fan. Fan type, air flow, inlet air temperature, air humidity and altitude substantially impact heat exchanger outputs. The colder the inlet air, the better will be your heat exchanger output. | |
| Model | CO2 Production (SCFH - Cubic feet per hour) |
Gas consumption (lbs per hour) |
| LP4X or NG4X 12 000 Btu |
4 | 0,5 |
| LP8X or NG8X 24 000 Btu |
8 | 1 |
Plug CO2 generator sense cord to a CO2 controller like iGS-061, iGS-100 or iGS-220 to control CO2 concentration in your grow room or greenhouse.For more information, contacts us at 1-888-577-6274.
For a precise control of CO2 concentration
IGS-061 CO2 Control with High Temperature Shut Off
iGS-100 Day and Night CO2 Control with Auxiliary Output
iGS-220 Day and Night Temperature or Relative Humidity and CO2
iGS-221 Combined control for temperature, humidity and CO2
For more information on CO2 use and safety in horticulture, see :