Contact us at 1-888-577-6274
or by filling out this short form.
Download our brochures to know more about the advantage of using our products.
FeaturesPlug sense cord in a timer or controller: when its outlet turns on, iLS4 is activated.

Light groups (4 x 1,000 W at a time, except for iLS4-120S) will turn ON at 2 minutes intervals. This technique reduces wear and tears on the electrical supply and allows for gradual night-time to daytime shifting in indoor grow rooms

| iLS4-120 (Supply line: 120 V, Outlets: 120 V) | ||||||
| 4 X 400 W | 4 X 600 W | 2 X 1000 W | ||||
|---|---|---|---|---|---|---|
| No second module | Total Amperage |
16A |
Total Amperage |
24A |
Total Amperage |
38A |
| 120 V breaker/fuse |
20A |
120 V breaker/fuse |
30A |
120 V breaker/fuse |
40A |
|
|
120 V supply line |
12GA |
120 V supply line |
10GA |
120 V supply line |
8GA |
|
|
Second iLS4-120 module |
Total Amperage |
32A |
Total Amperage |
38A |
||
| 120 V breaker/fuse |
40A |
120 V breaker/fuse |
40A |
|||
|
120 V supply line |
8GA |
120 V supply line |
8GA |
|||
| Second module line |
8GA |
Second module line |
8GA |
|||
|
Second iLS4 -120 module |
Total Amperage |
38A |
||||
| 120 V breaker/fuse |
40A |
|||||
|
120 V supply line |
8GA |
|||||
| Second module line |
8GA |
|||||
For more information, contact us at 1-888-577-6274.