FeaturesPlug sense cord in a timer or controller: when its outlet is activated, iLS4 switches ON.

| iLS4-240 (Supply line:240 V, Outlets: 240 V) | ||||||
| 4 X 400 W | 4 X 600 W | 4 X 1000 W | ||||
|---|---|---|---|---|---|---|
| No second module | Total Amperage |
8A |
Total Amperage |
12A |
Total Amperage |
19A |
| 240 V breaker/fuse |
15A |
240 V breaker/fuse |
20A |
240 V breaker/fuse |
30A |
|
| 240 V supply line |
14GA |
240 V supply line |
12GA |
240 V supply line |
10GA |
|
| Second iLS4-240 module 4 X 400 W |
Total Amperage |
16A |
Total Amperage |
20A |
Total Amperage |
27A |
| 240 V breaker/fuse |
20A |
240 V breaker/fuse |
30A |
240 V breaker/fuse |
40A |
|
| 240 V supply line |
12GA |
240 V supply line |
10GA |
240 V supply line |
8GA |
|
| Câble second module |
12GA |
Câble second module |
10GA |
Câble second module |
8GA |
|
|
Second iLS4-240 module |
Total Amperage |
20A |
Total Amperage |
24A |
Total Amperage |
31A |
| 240 V breaker/fuse |
30A |
240 V breaker/fuse |
30A |
240 V breaker/fuse |
40A |
|
| 240 V supply line |
10GA |
240 V supply line |
10GA |
240 V supply line |
8GA |
|
| Second module line |
10GA |
Second module line |
10GA |
Second module line |
8GA |
|
|
Second iLS4-240 module |
Total Amperage |
27A |
Total Amperage |
31A |
Total Amperage |
38A |
| 240 V breaker/fuse |
40A |
240 V breaker/fuse |
40A |
240 V breaker/fuse |
40A |
|
| 240 V supply line |
8GA |
240 V supply line |
8GA |
240 V supply line |
8GA |
|
| Second module line |
8GA |
Second module line |
8GA |
Second module line |
8GA |
|