Leaky iGS-RG1 CO2 regulator

Adjusting the CO2 release pressure with the black knob thus bringing the dial needle to point in the red zone does not  increase the CO2 flow rate. It may cause the regulator to leak CO2 from the pressure release orifice under the regulator.


If CO2 leaks through the orifice under the regulator, it is not faulty. Just turn the black knob counter clockwise to bring back the needle to point in the green zone, between 0.2 and 0.3 MPa.

To increase the CO2 flow rate in cubic feet per hour, add a second and even a third 20 lbs bottle or even use a 50 lbs bottle. Remember that a 20 lbs CO2 bottle cannot release more than 14 cubic feet of CO2 per hour.

BENOIT DUPUIS EXTINCTEURS (Ste-Julienne. Quebec, Canada) developped and offers a tubing kit to attach 2, 3, 4 + CO2 bottles to the same regulator.

Developped by Numérique Technologies

Last updated on : May 18, 2012